Username


Password

Forgot Password?

Preview

Sign-in free and Explore the Exciting World of BiomedExperts:
  • Over 1,800,000 Profiles
  • More than 3,500 Organizations worldwide
  • State of the Art Network Visualizations
  • Manage your own Profile
  • Locate Experts in your Country/Region
  • Locate Experts in your 1. and 2. Level Network
  • Connect to Experts Worldwide
2005Sambuceti Gianmario; Marzilli Mario; Mari Andrea; Marini Cecilia; Schluter Mathis; Testa Roberto; Papini Michaela; Marraccini Paolo; Ciriello Giuseppe; Marzullo Paolo; L'Abbate Antonio
Coronary microcirculatory vasoconstriction is heterogeneously distributed in acutely ischemic myocardium.
American journal of physiology. Heart and circulatory physiology 2005;288(5):H2298-305.
The classical model of coronary physiology implies the presence of maximal microcirculatory vasodilation during myocardial ischemia. However, Doppler monitoring of coronary blood flow (CBF) documented severe microcirculatory vasoconstriction during pacing-induced ischemia in patients with coronary artery disease. This study investigates the mechanisms that underlie this paradoxical behavior in nine patients with stable angina and single-vessel coronary disease who were candidates for stenting. While transstenotic pressures were continuously monitored, input CBF (in ml/min) to the poststenotic myocardium was measured by Doppler catheter and angiographic cross-sectional area. Simultaneously, specific myocardial blood flow (MBF, in ml.min(-1).g(-1)) was measured by 133Xe washout. Perfused tissue mass was calculated as CBF/MBF. Measurements were obtained at baseline, during pacing-induced ischemia, and after stenting. CBF and distal coronary pressure values were also measured during pacing with intracoronary adenosine administration. During pacing, CBF decreased to 64 +/- 24% of baseline and increased to 265 +/- 100% of ischemic flow after adenosine administration. In contrast, pacing increased MBF to 184 +/- 66% of baseline, measured as a function of the increased rate-pressure product (r = 0.69; P < 0.05). Thus, during pacing, perfused myocardial mass drastically decreased from 30 +/- 23 to 12 +/- 11 g (P < 0.01). Distal coronary pressure remained stable during pacing but decreased after adenosine administration. Stenting increased perfused myocardial mass to 39 +/- 23 g (P < 0.05 vs. baseline) as a function of the increase in distal coronary pressure (r = 0.71; P < 0.02). In conclusion, the vasoconstrictor response to pacing-induced ischemia is heterogeneously distributed and excludes a tissue fraction from perfusion. Within perfused tissue, the metabolic demand still controls the vasomotor tone.

Post to CiteULike

Sign in free and see...

Visualized networks:
See your personal network in
sophisticated graphical views
GeoTargeted Searches:
Locate experts around the world
and connect with global collaborators
Research Profiles:
See the visualized research activity
of experts around the globe
Sign-in to see more