Username


Password

Forgot Password?

Preview

Sign-in free and Explore the Exciting World of BiomedExperts:
  • Over 1.500.000 Profiles
  • More than 1.800 Organizations worldwide
  • State of the Art Network Visualizations
  • Manage your own Profile
  • Locate Experts in your Country/Region
  • Locate Experts in your 1. and 2. Level Network
  • Connect to Experts Worldwide
2006Reddy M C S; Hossner Kim L; Belk Keith E; Scanga John A; Yemm Robert S; Sofos John N; Smith Gary C
Detection of central nervous system tissue on meat and carcass-splitting band saw blade surfaces using modified fluorescent glial fibrillary acidic protein enzyme-linked immunosorbent assay sampling and extraction procedures.
Journal of food protection 2006;69(8):1966-70.
This study was conducted to determine optimal buffer pH, extraction procedure, and temperature for detecting central nervous system (CNS) tissue on meat surfaces and on carcass-splitting band saw blades using swab sampling. Glial fibrillary acidic protein (GFAP) is restricted to CNS tissue and has been used as a marker for CNS tissue presence in meat products. Sample preparation, extraction procedure, and extraction temperature of glial fibrillary acidic protein fluorescent enzyme-linked immunosorbent assay (GFAP F-ELISA) were modified to detect CNS tissue on meat surfaces and on carcass-splitting band saw blades. Maximum GFAP recovery was observed with an extraction buffer pH of 7.4. Extracting samples at room temperature by vortexing for 30 s in 1 ml of extraction buffer (phosphate-buffered saline [pH 7.4] plus 0.05% sodium dodecyl sulfate) consistently provided detection of GFAP on meat surfaces contaminated with 500 microg of spinal cord suspension per 50 cm2 and on carcass-splitting band saw blades contaminated with 20 microg of spinal cord suspension per 50 cm2. Recovery of GFAP was not affected by storing samples overnight at 4 degrees C. The current studies demonstrate the effectiveness of modified sampling procedures and preparations, sample extraction buffer pH, and extraction temperatures. These modifications introduced to the original F-ELISA sampling protocol result in asensitive and repeatable assay for detection of CNS tissue on meat surfaces and on carcass-splitting band saw blades.

Post to CiteULike

Sign in free and see...

Visualized networks:
See your personal network in
sophisticated graphical views
GeoTargeted Searches:
Locate experts around the world
and connect with global collaborators
Research Profiles:
See the visualized research activity
of experts around the globe
Sign-in to see more