Preview
Sign-in for full Details 
Sign-in free and Explore the Exciting World of BiomedExperts:
- Over 1.500.000 Profiles
- More than 1.800 Organizations worldwide
- State of the Art Network Visualizations
- Manage your own Profile
- Locate Experts in your Country/Region
- Locate Experts in your 1. and 2. Level Network
- Connect to Experts Worldwide
find experts for
Sign-in to see more
2006:
Carlson Stephanie K; Classic Kelly L; Hadac Elizabeth M; Bender Claire E; Kemp Bradley J; Lowe Val J; Hoskin Tanya L; Russell Stephen J
In vivo quantitation of intratumoral radioisotope uptake using micro-single photon emission computed tomography/computed tomography.
Molecular imaging and biology : MIB : the official publication of the Academy of Molecular Imaging 2006;
8(
6):.
PURPOSE: This study was undertaken to determine the ability of micro-single photon emission computed tomography (micro-SPECT)/computed tomography (CT) to accurately quantitate intratumoral radioisotope uptake in vivo and to compare these measurements with planar imaging and micro-SPECT imaging alone. PROCEDURES: Human pancreatic cancer xenografts were established in 10 mice. Intratumoral radioisotope uptake was achieved via intratumoral injection of an attenuated measles virus vector expressing the NIS gene (MV-NIS). On various days after MV-NIS injection, (123)I planar and micro-SPECT/CT imaging was performed. Tumor activity was determined by dose calibrator measurements and region-of-interest (ROI) image analysis. Agreement and reproducibility of tumor activity measurements were assessed by Bland-Altman plots and Lin's concordance correlation coefficient (CCC). RESULTS: Intratumoral radioisotope uptake was detected in all mice. Scatterplots demonstrate strong agreement (CCC = 0.93) between micro-SPECT/CT ROI image analysis and dose calibrator tumor activity measurements. The differences between dose calibrator activity measurements and those obtained with ROI image analysis of micro-SPECT alone and planar imaging are less accurate and more variable (CCC = 0.84 and 0.78, respectively). CONCLUSIONS: Micro-SPECT/CT can be used to accurately quantify intratumoral radioisotope uptake in vivo and is more reliable than planar or micro-SPECT imaging alone.
Post to CiteULike 
Sign in free and see...
Visualized networks:
See your personal network in
sophisticated graphical views
GeoTargeted Searches:
Locate experts around the world
and connect with global collaborators
Research Profiles:
See the visualized research activity
of experts around the globe
Sign-in to see more