Username


Password

Forgot Password?

Preview

Sign-in free and Explore the Exciting World of BiomedExperts:
  • Over 1.500.000 Profiles
  • More than 1.800 Organizations worldwide
  • State of the Art Network Visualizations
  • Manage your own Profile
  • Locate Experts in your Country/Region
  • Locate Experts in your 1. and 2. Level Network
  • Connect to Experts Worldwide
2008Ricci Davide; Mennander Ari A; Pham Linh D; Rao Vinay P; Miyagi Naoto; Byrne Guerard W; Russell Stephen J; McGregor Christopher G A
Non-invasive radioiodine imaging for accurate quantitation of NIS reporter gene expression in transplanted hearts.
European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery 2008;33(1):32-9.
OBJECTIVE: We studied the concordance of transgene expression in the transplanted heart using bicistronic adenoviral vector coding for a transgene of interest (human carcinoembryonic antigen: hCEA - beta human chorionic gonadotropin: betahCG) and for a marker imaging transgene (human sodium iodide symporter: hNIS). METHODS: Inbred Lewis rats were used for syngeneic heterotopic cardiac transplantation. Donor rat hearts were perfused ex vivo for 30 min prior to transplantation with University of Wisconsin (UW) solution (n=3), with 10(9) pfu/ml of adenovirus expressing hNIS (Ad-NIS; n=6), hNIS-hCEA (Ad-NIS-CEA; n=6) and hNIS-betahCG (Ad-NIS-CG; n=6). On postoperative day (POD) 5, 10, 15 all animals underwent micro-single photon emission computed tomography/computed tomography (SPECT/CT) imaging of the donor hearts after tail vein injection of 1000 microCi (123)I and blood sample collection for hCEA and betahCG quantification. RESULTS: Significantly higher image intensity was noted in the hearts perfused with Ad-NIS (1.1+/-0.2; 0.9+/-0.07), Ad-NIS-CEA (1.2+/-0.3; 0.9+/-0.1) and Ad-NIS-CG (1.1+/-0.1; 0.9+/-0.1) compared to UW group (0.44+/-0.03; 0.47+/-0.06) on POD 5 and 10 (p<0.05). Serum levels of hCEA and betahCG increased in animals showing high cardiac (123)I uptake, but not in those with lower uptake. Above this threshold, image intensities correlated well with serum levels of hCEA and betahCG (R(2)=0.99 and R(2)=0.96, respectively). CONCLUSIONS: These data demonstrate that hNIS is an excellent reporter gene for the transplanted heart. The expression level of hNIS can be accurately and non-invasively monitored by serial radioisotopic SPECT imaging. High concordance has been demonstrated between imaging and soluble marker peptides at the maximum transgene expression on POD 5.

Post to CiteULike

Sign in free and see...

Visualized networks:
See your personal network in
sophisticated graphical views
GeoTargeted Searches:
Locate experts around the world
and connect with global collaborators
Research Profiles:
See the visualized research activity
of experts around the globe
Sign-in to see more