Preview
Sign-in for full Details 
Sign-in free and Explore the Exciting World of BiomedExperts:
- Over 1,800,000 Profiles
- More than 3,500 Organizations worldwide
- State of the Art Network Visualizations
- Manage your own Profile
- Locate Experts in your Country/Region
- Locate Experts in your 1. and 2. Level Network
- Connect to Experts Worldwide
find experts for
Sign-in to see more
1995:
Low D A; Williamson J F
The evaluation of optimized implants for idealized implant geometries.
Medical physics 1995;
22(
9):.
The purpose of this paper is to investigate the utility of implant quality measures on single stepping-source brachytherapy treatment plans. Four dwell weight optimization algorithms were applied to four regular geometric implants: single plane, double plane, cuboid, and cylindrical. The dwell weight optimization schemes included equal weighing, two commercial optimization schemes (dose-point and geometric) and a variation of the Paterson-Parker distribution rules. The implant quality measures were investigated as a function of dose-per-integrated reference air kerma (IRAK) to eliminate bias resulting from a prescription choice. A particular dose per IRAK refers to a dose surface that is a function only of the relative dwell weight distribution and is therefore well suited to investigate dwell weight optimization schemes. The implant quality measures included the dose-nonuniformity ratio (DNR) developed by Saw and a coverage index to assess the isodose coverage relative to the implanted volume. These were termed direct quantities due to their clear clinical significance. Additional measures include the ratio of the implant dose-volume histogram (DVH) to that of a point source exhibiting the same IRAK (Rp) and the ratio of the optimized DVH to the equally weighted DVH (EWR). The widths of the Rp curves and depths of the EWR curves were used to characterize these indirect implant quality measures. To evaluate the effectiveness of both the direct and indirect measures, they were correlated with the DNR for an isodose surface that covered the implant (D0). The efficiency of the dwell weight distribution was examined by noting the dose-per-IRAK surface D0.(ABSTRACT TRUNCATED AT 400 WORDS)
Post to CiteULike 
Sign in free and see...
Visualized networks:
See your personal network in
sophisticated graphical views
GeoTargeted Searches:
Locate experts around the world
and connect with global collaborators
Research Profiles:
See the visualized research activity
of experts around the globe
Sign-in to see more